ZA-DJVVP3R Cable | Factory Direct Price & Datasheet

ZA-DJVVP3R Cable: Direct Factory Pricing & Full Spec Sheet

Electrical noise corrupts measurement signals long before you notice it on the HMI. A single ground loop or VFD transient can force an unplanned line stop, wiping out a shift’s output. The ZA-DJVVP3R cable isolates control and instrumentation loops from that interference. Its dual-shield architecture suppresses both low‑frequency capacitive coupling and high‑frequency radiated noise, keeping data streams intact and your plant running on schedule. You get a factory‑direct supply chain that removes distributor margin and ships with full mill traceability.

Individual Foil Shield + Overall Tinned‑Copper Braid

Each twisted pair is wrapped in an aluminium/polyester tape with 100% coverage. A dense tinned‑copper braid (≥ 85% coverage) sits over the bundle.
Low‑frequency magnetic fields and high‑frequency EMI are blocked at two distinct layers.
The result is a noise floor low enough for 4–20 mA analog sensors, RS‑485 serial buses, and 10 mV thermocouple circuits — no intermittent faults, no phantom trips, fewer hours spent chasing ghosts in the control cabinet.

IEC‑60332‑3‑22 Class A Flame Retardancy

The ZA designation means the cable passes the Category A vertical flame‑spread test.
It self‑extinguishes when the ignition source is removed and severely limits fire propagation along multi‑storey cable trays.
This helps your facility meet NFPA 70 / local fire‑code requirements, reduces smoke damage risk to adjacent assets, and can lower your insurance premium.

Class‑5 Flexible Stranded Conductors

Bare copper conductors built to IEC 60228 Class 5 flexibility.
The cable routes into tight control panels, cable chains, and conduit corners without kinking.
Panel builders finish terminations faster. Retrofit teams spend less time pulling cable, which cuts site labour cost on brownfield projects.

Factory‑Batch Traceability and No Middlemen

We sell direct from a single production site. Every metre carries a batch code linked to raw‑material certificates and test reports.
You eliminate mark‑up from distributors and brokers. Repeat orders are chemically and mechanically consistent, because the supply chain never changes hands.
Stable unit pricing across your annual contract and a documented chain of custody simplify vendor qualification audits.

Technical Specifications

Below are typical values for ZA-DJVVP3R cable. Request the full datasheet for the exact outer diameter and weight per km based on your pair count.

ParameterValue
ModelZA-DJVVP3R
ConductorStranded bare copper, IEC 60228 Class 5
Pair ShieldingAluminium/polyester tape, 100% coverage (individual pairs)
Overall ShieldingTinned copper braid, ≥ 85% coverage
InsulationFlame‑retardant PVC
Inner SheathBlack flame‑retardant PVC
Outer SheathFlame‑retardant PVC, ZA compound
Rated Voltage (rms)300 / 500 V
Test Voltage2 000 V, 5 minutes
Temperature Range−15 °C to +70 °C (fixed installation)
Min. Bending Radius8 × overall diameter
Relevant StandardsIEC 60332‑1‑2, IEC 60332‑3‑22 (Cat A), IEC 60228, IEC 60502‑1 (adaptation)

Industry Applications

  • Process control in chemical plants. Connects pressure transmitters and control valves across long tray runs. The aluminium tape keeps 4–20 mA loops immune to VFD noise from pump skids.
  • Building automation and BMS. Carries BACnet or Modbus RTU signals between DDC panels. The Class‑A flame retardancy satisfies fire‑engineering specs for plenum‑adjacent risers.
  • Wind turbine nacelle wiring. Twists with the pitch system without conductor fatigue. The tight braid shield protects analogue sensor signals from generator EMI.
  • Railway signalling and trackside enclosures. Withstands aggressive vibration and diesel particulate. Dual shielding preserves tone‑frequency integrity even in parallel with power cables.
  • Automated storage and logistics. Feeds encoders, barcode scanners, and Profibus nodes. The high‑flex conductors reduce termination breakage during pre‑assembly of switchgear carts.

International Compliance & QA

  • ✅ Flame retardancy tested per IEC 60332‑1‑2 (single cable) and IEC 60332‑3‑22 (Category A bundle)
  • ✅ RoHS 2.0 (Directive 2011/65/EU) compliant — lead‑free PVC compounds
  • ✅ CE marked under the Low Voltage Directive 2014/35/EU
  • ✅ Factory audited to ISO 9001:2015; batch records linked to raw‑material certifications
  • ✅ Tensile, elongation, and cold‑impact tests performed on every production lot — reports available upon request

FAQ

Q: What does the “ZA‑DJVVP3R” designation actually decode to?
ZA = flame‑retardant per IEC 60332‑3‑22 Category A. DJ = electronic‑computer cable. V = PVC insulation. V = PVC sheath. P3 = individual foil shield plus overall copper braid. R = flexible stranded conductor. That combination gives you a dual‑shielded, high‑flex cable built specifically for sensitive low‑energy circuits in a fire‑hardened jacket.

Q: Can you supply custom pair counts and overall diameter targets?
Yes. The base construction supports 1 to 24 twisted pairs (0.5 mm² to 2.5 mm²). We can adjust the inner‑sheath thickness to match your conduit‑fill calculation. Send us a cable schedule and we will confirm the achievable outer diameter before tooling.

Q: What lead time applies for a 5 km trial order?
Standard products up to 20 pairs usually ship in 10–12 working days after drawing approval. Custom configurations add 3–5 days for initial extrusion setup. Express air‑freight is available if you need a commissioning deadline met. We will lock the lead time in writing with the pro‑forma invoice.

Request the Full Datasheet and Volume Pricing

Specify the signal type, pair count, and required length. Our application engineers will return a complete data pack — including attenuation, capacitance, and L/R values — along with a landed‑cost quotation for your nearest port. Ask for a free sample length if you need to verify termination performance on your own tools.