4 Core 1mm² Shielded Cable | Double-Layer PVC Transparent Sheath | Yellow/Green Ground Wire | General Cavi Standard

Description

Tired of signal interference and messy wiring that fails inspection?

You know the struggle. You are setting up a new control panel or fixing a machine. You buy cheap cable to save money. But then, the noise starts. Motors hum. Sensors give wrong readings. The screen flickers. You waste hours checking the machine, but the problem is the wire. It picks up noise because the shielding is bad.Or maybe the cable jacket cracks when you bend it. Or the print on the wire rubs off after a week. You cannot tell which wire is which. You mix up the ground wire. This is dangerous. It can short-circuit your expensive equipment. It can even cause a fire.You need a cable that works right the first time. You need a cable you can see through. You need a cable that protects your signals and keeps your team safe. This is why we built our 4-core 1 square millimeter shielded wire with a double-layer PVC transparent outer sheath. It solves these headaches before they start.


What makes this cable different from the rest?

This is not just a standard wire. It is a heavy-duty solution for tough environments. We use high-quality materials that meet strict European standards like VDE and IEC. Let’s look at what you get inside the jacket.

The “See-Through” Advantage

Most cables have a black or grey jacket. You have to cut it to see the wires inside. Our cable has a double-layer PVC transparent outer sheath. This is a game-changer. You can see the color codes and the numbers on the insulation without stripping the cable.Why does this matter?

  • Fast Installation: You don’t waste time guessing which wire is phase A or phase B.
  • Easy Troubleshooting: If there is a fault, you can see exactly where the damage is on the outer layer.
  • Professional Look: It looks clean and high-tech in your control cabinet.
Numbered Cores for Zero Mistakes

We know that wiring errors cost money. That is why we use numbered cores. Each insulated conductor has a printed number. You don’t have to memorize color codes. You just match the number on the wire to the number on your terminal block. It is simple. It is foolproof.

The Yellow-Green Safety Standard

Safety is not optional. We include a dedicated yellow-green grounding wire. This is the international standard for earth wires. You cannot miss it. It ensures that any stray voltage goes safely to the ground. This protects your operators from shocks. It also protects your sensitive electronics from voltage spikes.

Superior Shielding Against Noise

We wrap the cores in a tinned copper braid shield. The coverage is 80% to 85%. This is much better than cheap foil shields. It acts like a cage. It keeps outside noise out. It keeps your signal noise in. This is critical for data lines, sensor lines, and audio equipment. The shield is also tinned. This means it does not rust or corrode easily in wet or humid places.


Technical Specifications You Can Trust

We believe in transparency. Here are the hard numbers for our 4-core 1mm² shielded cable. These specs ensure it works in real-world conditions.

ParameterSpecification
ConductorStranded bare copper (Class 5 flexibility)
Cross Section1 x 1.0 mm² (approx 0.06 inches)
Number of Cores4 (3 Phase + 1 Ground/Neutral)
Insulation MaterialSpecial PVC (Polyvinyl Chloride)
Sheath MaterialDouble-layer Transparent PVC (TM2)
ShieldingTinned copper braid (80-85% coverage)
Voltage Rating450/750 V (0.6/1 kV)
Test Voltage3000 V (2.5 kV for some variants)
Temperature Range-35°C to +60°C (Static) / -5°C to +70°C (Flexing)
Bending Radius8x cable diameter (Fixed) / 12x (Flexing)
Flame RetardancyIEC 60332-1-2 (Self-extinguishing)
Oil ResistanceYes (Suitable for oily environments)
StandardsCE, RoHS, REACH, VDE 0295, IEC 60228

Let’s break down these numbers in plain English:

  • Class 5 Copper: This means the wire is very flexible. You can bend it around tight corners in a machine without breaking the copper strands. Solid wire is stiff and breaks. Our wire moves with the machine.
  • 450/750 V: This is the standard voltage for low-voltage control circuits. It handles up to 750 volts safely.
  • -35°C to +60°C: This cable works in freezers and hot factories. The PVC does not get brittle in the cold or melt in the heat.
  • 8x Bending Radius: You can bend this cable into a circle 8 times its thickness. It is great for robot arms and moving parts.

Where should you use this cable?

This wire is a workhorse. It fits almost any low-voltage application where you need signal integrity and safety. Here are the top places we see our customers use it:

Industrial Automation & Robotics

Factories use Programmable Logic Controllers (PLCs). These brains control the machines. They need clean signals. If the cable picks up noise from a nearby motor, the robot arm might crash. Our shielded cable prevents this. The transparent sheath lets technicians see the wire numbers quickly during maintenance.

CCTV and Security Systems

Security cameras need power and video signals. Sometimes they are outside. They need to resist rain and UV light. Our PVC sheath is UV resistant. The shield stops interference from nearby power lines, which can cause lines on your video screen.

Process Control & Instrumentation

In chemical plants or food processing, sensors measure temperature, pressure, and flow. These are low-voltage signals. A bad cable can show the wrong temperature. This can ruin a batch of product or cause a safety hazard. The numbered cores ensure you connect the sensor to the right controller port every time.

Audio and Broadcast

For microphones and speaker lines, interference is the enemy. It causes hum and buzz. The 85% copper braid shield blocks radio frequency interference (RFI) and electromagnetic interference (EMI). The double-layer transparent jacket looks professional in studios where cables are visible.

Building Management Systems (BMS)

HVAC systems, lighting controls, and fire alarms all use shielded control cables. The yellow-green ground wire is essential for fire safety compliance. The flame-retardant jacket stops the fire from spreading along the cable run.


Why buy from us? We speak your language.

We are not just a factory. We are your partner in wiring solutions. We understand that you have deadlines. You have budgets. You have quality standards to meet.We fix the common problems you face:

  • Problem: “The print on the wire rubs off.”
    • Our Fix: We use high-durability ink that meets ISO 60811-402 standards. It stays on even when you strip the wire.
  • Problem: “The cable is too stiff to install.”
    • Our Fix: We use fine-strand copper (Class 5). It is soft and easy to pull through conduits.
  • Problem: “I don’t know if this cable is safe.”
    • Our Fix: Every batch is tested for high voltage and continuity. We provide test reports. We follow the Low Voltage Directive (LVD) and CE standards strictly.

Customization is our strength:Need a different color for the sheath? We can do blue, orange, or black. Need a different length? We cut to your exact meter requirement. Need a specific print on the insulation? We can print your company logo or custom numbers. Just tell us what you need.We care about the planet:We follow RoHS and REACH regulations. Our materials are free from lead, mercury, and cadmium. It is safe for your workers and safe for the environment when you dispose of it.


Frequently Asked Questions (FAQs)

Q: Is this cable suitable for outdoor use?A: Yes, but it needs protection from direct sunlight for long periods. The PVC has UV resistance, but we recommend putting it in a conduit or trunking for permanent outdoor installation to extend its life to 20+ years.Q: Can I use this for 24V DC circuits?A: Absolutely. It works perfectly for 24V, 110V, or 220V AC/DC control circuits as long as you stay under the 450/750V rating.Q: How do I ground the shield?A: You should connect the drain wire (or the shield itself) to the earth ground at one end only, usually the control panel end. This prevents ground loops which can cause noise.Q: What is the difference between “transparent” and “clear”?A: They mean the same thing here. You can see the inner wires. It helps a lot when you are wiring a complex panel with 50 different wires. You save hours of labor time.Q: Do you provide samples?A: Yes. We can send you a 10-meter sample roll so you can test the flexibility and check the print quality before you place a big order.


Don’t let bad wiring ruin your project. Get a quote now.

You have seen the specs. You know the benefits. You understand the value of a transparent, numbered, shielded cable that lasts. Now it is time to act.Do not gamble with cheap, generic wire that will fail in six months. Invest in a cable that meets General Cavi standards and European quality. It costs a little more upfront, but it saves you thousands in downtime, repairs, and re-wiring labor.We are ready to ship. We have stock in our warehouse, or we can produce a custom batch just for you. We ship worldwide. We handle the export paperwork so you don’t have to stress.Click the “Get Quote” button now. Tell us how many meters you need and where to send them. Our sales team will reply within 24 hours with the best price and the fastest shipping option.Let’s wire your success together. Order today.