11.5mm Japanese Imported Sun 12-Core 0.35mm² Twisted Pair Shielded Signal Data Cable (6P 22AWG) – EMI Protection for Industrial Automation & Robotics

Description

Is your signal unstable? Do you hate noise interference?

You are running a complex machine. The robot arm stops moving. The sensor gives wrong data. The screen has snow. You check the connection, and it looks fine. But the problem comes back. This is not your device’s fault. It is the cable’s fault.Cheap cables act like antennas. They pick up noise from motors, power lines, and other machines. This noise kills your signal. It causes errors. It stops production. It wastes your time and money. You need a cable that blocks noise. You need a cable that keeps the signal pure. You need the Japanese imported Sun 12-core shielded cable.


What makes this cable special?

This is not a standard wire. It is a high-performance data cable. The name tells you everything. It has 12 cores. This means 6 pairs of wires. Each pair is twisted together. Why twist? Twisting cancels out noise. If one wire picks up noise, the other wire picks up the opposite noise. They cancel each other. This is the basic secret of good data cables.But twisting is not enough. This cable has a shield. The shield is a metal layer around the wires. It acts like a wall. It stops outside noise from getting in. It also stops your signal from leaking out. This is critical for EMI (Electromagnetic Interference) protection. If you work near heavy motors or VFDs (Variable Frequency Drives), you must have this shield. Without it, your data will be corrupt.


Technical Specs: Simple numbers for real use

We know you need exact details. Here is the breakdown of this 11.5mm Japanese imported Sun cable:

Core and Gauge Details
  • Conductor: 22 AWG. This is the American Wire Gauge.
  • Cross-Section: 0.35mm². This is the metric size. It is a standard size for signal and data. It is not too thick. It is not too thin. It is just right for most control signals.
  • Pairs: 6 Pairs (12 Cores total). You get 6 independent channels. This is great for multi-axis robots or complex sensor arrays.
  • Material: High-purity copper. Often tin-plated. Tin-plating stops rust. It makes the wire last longer in wet or humid places.
Cable Structure and Shielding
  • Shield Type: Foil Shield + Braided Shield (SF/UTP or F/FTP). We use both foil and braid. Foil is great for high-frequency noise. Braid is great for low-frequency noise and physical strength. Using both gives you the best protection.
  • Drain Wire: Yes. We include a tinned copper drain wire. This makes grounding easy. You do not need to strip the main shield. Just connect the drain wire to the ground. It saves you time.
  • Twist Rate: Optimized for data. The pairs are twisted at different rates. This stops the pairs from interfering with each other (crosstalk).
Outer Jacket and Dimensions
  • Outer Diameter: 11.5mm. This is the total thickness. It is compact for a 12-core shielded cable. It fits in most cable chains (drag chains).
  • Jacket Material: PVC or PUR.
    • PVC: Standard. Good for indoor use. Flexible. Resistant to oil and acid.
    • PUR: Premium. Highly flexible. Extremely resistant to oil, abrasion, and chemicals. It does not crack when bent.
  • Temperature Rating: Usually -20°C to +80°C (or higher for special grades). It handles heat well.
  • Voltage Rating: 300V or 600V. This is for the insulation between wires. It is safe for low-voltage control circuits (24V, 48V).

Where should you use this cable?

This cable is built for tough jobs. It is not for your home speaker. It is for professional use. Here are the best places to use it:

Industrial Automation and Robotics

This is the #1 use case. Robots move a lot. Their cables bend millions of times. Standard cables break. The copper wires snap. This cable is designed for “flex life.” It has a special stranding (many thin wires twisted together) instead of one solid wire. It bends easily without breaking. It is perfect for robot arms, CNC machines, and assembly lines.

Instrumentation and Sensors

You have many sensors in a factory. Pressure sensors. Temperature sensors. Proximity sensors. You need to send data to a PLC (Programmable Logic Controller). This cable carries multiple signals in one go. The shielding ensures the sensor reading is accurate. You do not get false triggers.

Audio and Video Broadcast

Balanced audio lines need twisted pairs. This cable has 6 pairs. You can use it for multi-channel audio or intercom systems. The shield stops “hum” and “buzz” from power lines. It keeps the audio clean.

Outdoor and Direct Burial

If you choose the PE (Polyethylene) or PUR jacket, this cable is tough. It resists UV rays from the sun. It resists moisture. You can bury it in the ground or hang it outside. It protects the delicate copper inside.


Why choose the “Japanese Imported Sun” brand?

You might ask, “Why this brand?” The answer is quality control. Japanese cable standards are strict. “Sun” is a known brand for reliability.

  • Consistency: Every meter is the same. The copper is pure. The insulation is even. There are no thin spots.
  • Longevity: These cables do not crack. They do not become brittle after a year. They work for 5, 10, or 15 years.
  • Performance: The shielding coverage is high (usually >85% or even 95%). Cheap cables have gaps in the shield. This cable does not. It blocks almost all interference.

When you buy this, you are buying peace of mind. You are not fixing cables next month. You are working today.


Installation Tips for Best Results

To get the best performance, follow these simple rules:

  1. Ground the Shield: This is the most important rule. The shield only works if it is grounded. Connect the drain wire to the earth ground at one end (usually the control panel end). If you ground both ends, you might get a “ground loop.” This can cause noise too. So, ground one end only for most data signals.
  2. Respect Bend Radius: Do not bend the cable too sharp. The minimum bend radius is usually 10 times the diameter. For this 11.5mm cable, do not bend it tighter than 115mm (about 4.5 inches). If you bend it sharper, you damage the shield and the wires.
  3. Separate from Power: Even with a shield, keep this cable away from high-voltage power lines. If they run parallel, keep a gap. If they cross, cross at 90 degrees. This reduces interference even more.
  4. Use Proper Connectors: Use shielded connectors (like M12 or RJ45 with metal shells). Make sure the connector shell touches the cable shield. This keeps the shield continuous all the way to the device.

Frequently Asked Questions

Can I use this for Ethernet (LAN)?

No. This is for signal and control data (RS485, RS232, CAN bus). It is not Cat5e or Cat6. It does not have the impedance control (100 Ohm) needed for high-speed internet. Use it for sensors and machines, not for computers.

Is 22AWG strong enough for power?

No. 22AWG is for signals only. Do not use it to power a motor or a heater. The current is too high (max ~0.9A for chassis wiring). It will overheat. Use it for data. Use a separate cable for power.

What is the difference between PVC and PUR jacket?

PVC is cheaper and good for general indoor use. It is stiff when cold. PUR is more expensive but much better. It is very flexible in cold weather. It does not get sticky in heat. It resists oil and chemicals better. If your machine moves or is in a dirty factory, choose PUR.

How do I strip the jacket?

Use a proper wire stripper. Do not use a knife. You might nick the copper or cut the shield. A nick can cause a break later. Set the stripper to 11.5mm. Strip slowly.


Get your custom quote today

You need a reliable cable. You need it to work every time. You need it to stop the noise. This 11.5mm Japanese imported Sun 12-core shielded cable is the answer. It has the right size, the right shielding, and the right quality.We are a factory. We can cut this cable to your exact length. We can add connectors (M12, D-Sub, flying leads). We can make custom jackets.Do not let bad cables stop your business. Send us an inquiry now. Tell us your length, your connector type, and your jacket choice. We will send you a price within 24 hours. Test a sample first. See the difference quality makes.Click “Contact Us” or “Get a Quote” now. Let’s solve your signal problems together.